Place in the house · Heat pump

Where does the heat pump's heat come from?

A heat pump doesn't make heat. It takes it from the outdoor air and carries it into the house, much like a sponge that moves water from one place to another. What you have to pay for is the electricity that does the carrying.

Even in winter, the outdoor air isn't empty of heat. Outside, the heat pump's refrigerant is even colder than the air. That's why it absorbs heat, even in frost. Inside the unit it is compressed, which makes it hot, and the heat passes into the heating water. Then it expands, turns ice-cold again and fetches the next load. The compressing is the work, and that's what the heat pump needs electricity for.

You don't pay for the heat from the outdoor air. You pay for the electricity that carries it into the house. That's the advantage: one kilowatt-hour of electricity becomes several kilowatt-hours of heat, because most of it comes from the surroundings and only the smaller part from the socket.

Exactly how many is given by the coefficient of performance, or COP. It's the ratio of heat delivered to electricity used. For a typical air-to-water heat pump at an outdoor temperature of 2 °C, it is 4.1 when the heating water enters the house at 35 °C. At a flow temperature of 45 °C it drops to 3.2, at 55 °C to 2.5. Same machine, same outdoor air, but considerably more electricity for the same heat.

The reason is simple: the higher the heat has to be lifted, the more work it takes. In a hard frost of −7 °C the gap becomes visible. With a flow temperature of 35 °C, the pump delivers roughly three times as much heat as the electricity it uses, with 55 °C only about twice as much.

As a rule of thumb: every degree of flow temperature costs around 2.5 % electricity. So ten degrees more means about a quarter more electricity for the same heat. That's why it pays to set the flow temperature only as high as your house really needs.

You can check the math on the model house, built in 1967. It is estimated to need around 21,000 kWh of heat a year. With a flow temperature of 55 °C, that takes roughly 8,400 kWh of electricity, with 45 °C roughly 6,600 kWh. That saves about a fifth, which at 30 ct per kWh is a good €500 a year. This difference comes purely from how high the heat is lifted, not from a better machine.

More on this in the video on flow temperature (in German, with translated chapters and transcript).