Place in the house · Flow temperature
What exactly is the flow temperature?
The heat pump heats water, and the water flows through pipes to the radiators. The temperature at which it sets off is called the flow temperature. It's the one value on the controller that decides how much electricity your house needs.
The water travels in a loop. The heat pump heats the water. It flows through the pipes to every radiator, gives off its heat to the room there and comes back cooled down. The temperature at which the water sets off is called the flow temperature. The temperature at which it comes back is called the return temperature.
If the flow temperature is high, the radiator gets really hot. If it's low, it only gets warm. Whether that's enough depends on two things: how big the radiator is and how much heat the room is losing at that moment. A large radiator can do the job even when it's lukewarm. A small one can't. Then it gets cold in exactly that room.
That's the mistake many people make. They turn the flow temperature down for the whole house without first knowing which room will give up first. If you just try it, you may end up sitting in a cold living room in January.
Why is turning it down worth it at all? Because every step up costs electricity. The hotter the water needs to be in the end, the harder the heat pump has to squeeze the heat together. As a rule of thumb, every degree of flow temperature costs around 2.5 % more electricity. So ten degrees more means roughly a quarter more electricity, and that for exactly the same heat in the house.
The start of the video shows how big the difference gets. Two houses, both built in 1967, same heat pump, same weather, 21 degrees everywhere inside. And yet one of the two houses pays a good 500 euros more for electricity every year. The reason is a single value on the controller: the flow temperature.
For the model house, you can check the math. It is estimated to need around 21,000 kilowatt-hours of heat a year. With a flow temperature of 55 degrees, that takes around 8,400 kilowatt-hours of electricity, with 45 degrees around 6,600. That's a fifth less. At 30 cents per kilowatt-hour, that's a good 500 euros, every year. Your house may need more or less heat, but the fifth stays.
So the art is to set the flow temperature as low as possible, but no lower. You find out which room is your bottleneck from the radiators and from the heating curve. Both are explained in the other places in the house.
More on this in the video on flow temperature (in German, with translated chapters and transcript).